Hydrant System

Hydrant System
Hydrant System

Hydrant System Specification

  • Coating Type
  • Red Epoxy Powder Coating/Hot Dip Galvanized
  • Technology
  • Wet Riser System, Mechanical & Manual Operation
  • Fire Extinguisher Type
  • Fire Hydrant System (Not Portable)
  • Working Temperature
  • Up to 50C (General); Materials suitable for ambient conditions
  • Coverage Area
  • As per NBC/IS Standard; typically covers all floors and sections of protected premises
  • Connectivity Type
  • Direct Water Supply with Fire Pump, Option for Tank Integration
  • Control Type
  • Manual Activation via Landing Valve or Fire Hose Reel
  • Fire Class
  • Class A and B Fires (Solids & Flammable Liquids)
  • Shape
  • Round (Main Pipes & Branches)
  • Mounting Type
  • Fixed, Vertical/Horizontal as per design
  • Installation Type
  • Wall Mounted/Surface Mounted/Stand Post
  • Max Flow Rate
  • Up to 900 LPM (Liter per Minute) depending on model and system pressure
  • Diameter
  • 63 mm (Standard Branch); Main Pipe 80 mm or as per design
  • Pressure
  • Standard 7 kg/cm (Can be designed as per site requirements)
 

Hydrant System Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
 

About Hydrant System

With the aid of untiring and consistent effort of our staff, we are able to export and supply the assortment of Hydrant System. These are extremely suitable in extinguishing big fires. Considered to be the efficient fire detection solution, our range is procured from the remarkable vendors. Offered systems have excellent fire sensing capacity and can easily detect the fire at beginning phase. We deliver our Hydrant System to the client's end within the stipulated time frame.

Features:

  • Optimum performance
  • Easy installation
  • Durable in standards



Efficient Fire Protection for Diverse Settings

This hydrant system is designed to address the safety needs of various establishments, from residential and commercial buildings to industrial complexes. It uses a wet riser system that guarantees consistent water supply in emergencies, providing reliable coverage across all premises. The manual activation feature via landing valves or hose reels ensures immediate deployment during fire outbreaks.


Robust Construction and Flexible Installation

Manufactured with high-grade materials suitable for up to 50C, the system offers surface, wall-mounted, or stand post options to match any buildings requirements. Coated with red epoxy powder or hot dip galvanization, it resists corrosion and ensures long-term durability, making it ideal for both indoor and outdoor environments.

FAQs of Hydrant System:


Q: How is the hydrant system activated during an emergency?

A: The hydrant system is manually activated using a landing valve or fire hose reel. Personnel turn the handwheel or lever to release water, allowing immediate response to fire incidents.

Q: What types of fires can this hydrant system effectively combat?

A: This system is designed for Class A (combustible solids) and Class B (flammable liquids) fires, ensuring comprehensive protection in varied settings such as offices, warehouses, and factories.

Q: Where can the hydrant system be installed within a premises?

A: Installations are highly flexible: the system can be wall-mounted, surface-mounted, or installed as a stand post, depending on site design and coverage requirements as per NBC/IS standards.

Q: What is the maximum water flow rate provided by this hydrant system?

A: Depending on the model and system pressure, the hydrant system can deliver up to 900 liters per minute, supporting rapid suppression of large-scale fires.

Q: When should this system be serviced or maintained?

A: Scheduled maintenance should follow local fire safety regulations and manufacturer guidelines to ensure the system functions optimally. It is generally inspected periodically as part of fire safety protocols.

Q: What are the benefits of the wet riser technology used in this system?

A: Wet riser technology keeps the pipework pressurized with water at all times, enabling instant water delivery during emergencies for maximum effectiveness and reliability.

Q: How does the hydrant system connect to the buildings water supply?

A: The system supports direct connection to a pressurized water supply using a fire pump, and there is also an option to integrate with a dedicated water tank as per site design preferences.

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Protection Systems Category

Fire Sprinkler Systems

Fire Sprinkler Systems

Price Range 250.00 - 250.00 INR / Unit

Minimum Order Quantity : 1 Unit

Fire Class : A, B, C

Control Type : Automatic

Mounting Type : Ceiling/Wall Mounted

Diameter : 15 mm to 25 mm

Gas Based Fire Suppression Systems

Gas Based Fire Suppression Systems

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Fire Class : A, B, C, E

Control Type : Automatic and Manual

Mounting Type : Wall / Floor / Skid mounted

Diameter : 180 mm

Modular Ceiling Mounted

Modular Ceiling Mounted

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Fire Class : A, B, and C

Control Type : Automatic

Mounting Type : Ceiling Mount

Diameter : 150 mm

Metal Fire Bucket

Metal Fire Bucket

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Fire Class : General Solid & Flammable Liquid Fires (Class A & B)

Control Type : Manual Handle

Mounting Type : Wall Hanging/Portable

Diameter : Approx. 12 inches (30 cm)



"We mainly deal in end user products such as fire fighting systems."
Back to top