Sidewall Sprinkler System

Sidewall Sprinkler System
Sidewall Sprinkler System

Sidewall Sprinkler System Specification

  • Technology
  • Wet Pipe Sprinkler System
  • Operating Pressure
  • 0.5 - 1.2 MPa
  • Coverage Area
  • Up to 18 m per sprinkler
  • Features
  • Quick Response, Uniform Water Distribution, Corrosion Resistant
  • Fire Class
  • Class A & B
  • Installation Type
  • Wall Mounted, Sidewall Orientation
  • Mounting Type
  • Wall Mount
  • Fire Extinguisher Type
  • Sprinkler Head
  • Control Type
  • Automatic
  • Working Temperature
  • 57C, 68C, 79C (varies by bulb color)
  • Connectivity Type
  • Direct Piping Connection
  • Shape
  • Semi Circular Spray Pattern
  • Coating Type
  • Chrome Plated
  • Application
  • Fire Protection in Commercial and Residential Buildings
  • Max Flow Rate
  • 80 L/min
  • Capacity
  • Single Outlet
  • Diameter
  • 15 mm (1/2 inch)
  • Pressure
  • 0.35 - 1.2 MPa
 

Sidewall Sprinkler System Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
 

About Sidewall Sprinkler System

We are recognized Fire Sprinkler system supplier and trader in Mumbai Maharashtra India.We are prominent firm engaged in trading and supplying Fire Sprinkler UL / Fm/Lpcb of excellent quality. This is used for fire protection systems for modern buildings and is mandated by the local fire brigade, insurance authorities and other regulatory bodies. Customers can avail customized sprinklers from us as per their needs and requirements. These commercial fire sprinklers are manufactured from quality-tested components and are highly demanded by our clients.

We have five type of fire sprinkler system, Concealed Sprinkler system, Pendent sprinkler system, Sidewal sprinkler system all are UL / Fm/Lpcb type Sprinklers and, Foam based System, Water Based System.



Efficient Wall-Mounted Fire Suppression

Designed specifically for wall installation, these sidewall sprinklers seamlessly cover up to 18 m per unit, delivering targeted protection for both commercial and residential structures. The direct piping connection facilitates streamlined integration into new or existing fire safety systems without complicated retrofitting, while the semi-circular spray pattern enhances water coverage along walls where ceiling installation is not feasible.


Compliance and Versatile Performance

Each sprinkler conforms to global safety standards, featuring UL Listing and FM Approval. Reliable at pressures between 0.5 and 1.2 MPa, the devices can handle varying fire scenarios efficiently. The option for either standard or quick response bulbs allows for flexibility in different environments, while the corrosion-resistant construction ensures long-term, dependable operationeven in challenging conditions.

FAQs of Sidewall Sprinkler System:


Q: How is a sidewall sprinkler system installed for maximum effectiveness?

A: Sidewall sprinkler heads are installed horizontally on walls, typically near the ceiling, to provide a semi-circular spray pattern that covers up to 18m per unit. Installation involves direct piping connections using either 1/2" BSPT or NPT threads. Professional installation is recommended to ensure compliance with NFPA 13 and optimal coverage in commercial or residential buildings.

Q: What materials and finishes are available for these sprinkler systems?

A: The sidewall sprinkler heads are manufactured from durable brass or stainless steel, with a choice of polished, chrome-plated, or painted finishes. These surface options provide superior corrosion resistance and aesthetic compatibility with a variety of interior designs, enhancing both longevity and appearance.

Q: When should standard or quick response types be used?

A: Standard response sprinklers are ideal for commercial settings where property protection is prioritized, while quick response models are recommended for spaces where life safety is critical, like residential buildings or occupied offices. The quick response variant utilizes a 5 mm bulb for rapid activation during fire events.

Q: Where are sidewall sprinkler systems typically applied?

A: Sidewall sprinkler systems are commonly used in locations where ceiling-mounted systems are impractical, such as corridors, offices, apartments, hotels, or buildings with obstructions. They provide effective fire protection for both commercial and residential environments throughout India.

Q: What is the process for maintaining a sidewall sprinkler system?

A: Routine inspections and periodic testing are necessary to ensure performance and compliance. This includes checking for obstructions, verifying operating pressure (0.5 - 1.2 MPa), inspecting for corrosion or physical damage, and confirming the appropriate working temperature according to the installed bulb color (57C, 68C, or 79C).

Q: How does the system provide uniform water distribution during a fire emergency?

A: The semi-circular spray pattern, with a spray angle of 90, ensures water is delivered evenly along walls and adjacent spaces, effectively suppressing Class A and B fires. The discharge coefficient (K=5.6) enables a flow rate of 80 L/min at 1 bar, promoting efficient fire control throughout the coverage area.

Q: What are the key benefits of choosing this sidewall sprinkler system?

A: Benefits include quick or standard response activation, UL and FM certification, robust corrosion-resistant construction, uniform water distribution, and compatibility with wet pipe sprinkler technology. These features support reliable fire protection, safety compliance, and ease of integration for new or retrofit projects.

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Sprinkler system Category

UL Sprinklers

UL Sprinklers

Price Range 250.00 - 250.00 INR / Unit

Minimum Order Quantity : 1 Unit

Control Type : Automatic

Fire Extinguisher Type : Sprinkler

Working Temperature : 57C, 68C, 79C, 93C (varies by model)

Mounting Type : Ceiling/Pendant

Glass Bulb Sprinkler

Glass Bulb Sprinkler

Price Range 250.00 - 250.00 INR / Unit

Minimum Order Quantity : 1 Unit

Control Type : Automatic

Fire Extinguisher Type : Sprinkler Head

Working Temperature : 57C, 68C, 79C, 93C, 141C (Available in Multiple Ratings)

Mounting Type : Ceiling/Wall Mounted



"We mainly deal in end user products such as fire fighting systems."