Beam Smoke Detector Specification

  • Features
  • Early Smoke Detection, Wide Area Monitoring, Low Maintenance
  • Technology
  • Infrared Beam Smoke Detection
  • Voltage
  • 24V DC (Nominal)
  • Connectivity Type
  • Wired
  • Shape
  • Rectangular/Slim
  • Working Temperature
  • -10C to +55C
  • Coverage Area
  • Up to 1400 Square Meters
  • Mounting Type
  • Surface Mount
  • Installation Type
  • Ceiling or Wall Mounted
  • Control Type
  • Automatic
  • Application
  • Smoke Detection in Large Open Areas
  • Adjustment
  • Automatic gain control for alignment
  • Operating Humidity
  • 0% to 93% RH, non-condensing
  • Material
  • ABS Engineering Plastic
  • Compliance
  • EN54-12 Certified
  • Response Time
  • < 10 seconds
  • Range
  • Up to 100 meters (adjustable)
  • Alarm Outputs
  • Relay Contacts (NO/NC)
  • Fault Outputs
  • Relay Contacts (NO/NC)
  • Alarm Sensitivity
  • Selectable, Typically 1.0 3.8% obs/m
  • Dimension
  • Approx. 210mm x 120mm x 90mm
 

Beam Smoke Detector Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
 

About Beam Smoke Detector

Cease Fire & Electrical Services is a leading supplier and distributor of high-performance Beam Smoke Detector that is equipped with highly active smoke sensors that automatically give the signal to the central control panel of the fire fighting system to release extinguishing fluids. The hard ABS plastic of this device provides high strength to weight ratio that gives excellent protection from high-temperature flames, dirt, and moisture. Buyers can get this Beam Smoke Detector from us in bulk at a reasonable and low price range.



Early Detection for Large Spaces

Employing infrared beam technology, this detector delivers reliable and fast smoke detection in expansive environments. Its broad coverage area and rapid response time make it ideal for safeguarding open-plan facilities, providing peace of mind through early warning against fire threats.


Flexible Sensitivity and Easy Setup

Selectable sensitivity levels and automatic gain control enable users to tailor the device to their specific environment and ensure accurate detection. Installation is convenient on both ceilings and walls, and maintenance routines are minimal, making it a practical solution for busy spaces.


Certified Safety and Trusted Performance

The Beam Smoke Detector complies with EN54-12 standards, ensuring dependable quality and performance. Its robust design and versatile mounting options make it suitable for dealers, suppliers, and service providers catering to clients across India.

FAQs of Beam Smoke Detector:


Q: How does the Beam Smoke Detector function in large open areas?

A: The Beam Smoke Detector utilizes infrared beam technology to continuously monitor large spaces and detect smoke by analyzing the obscuration of the transmitted beam. This approach makes it effective in environments where conventional point detectors may not provide comprehensive coverage.

Q: What is the process for installing this beam smoke detector?

A: The detector is designed for surface mounting on ceilings or walls. During installation, automatic gain control assists with alignment to achieve optimal performance. The device should be connected to a 24V DC power supply and integrated with the buildings fire alarm system via its relay contacts.

Q: Where can this smoke detector be effectively used?

A: This detector is ideally suited for large, open indoor areas such as warehouses, factories, shopping malls, exhibition halls, and airports, where wide area smoke detection is essential for early warning.

Q: When should I consider adjusting the alarm sensitivity?

A: Alarm sensitivity is adjustable (typically 1.03.8% obscuration/meter) to match the environmental conditions of the installation site. Adjustments should be made during setup or following significant changes to the monitored space to maintain reliable detection and minimize false alarms.

Q: What maintenance does the beam smoke detector require?

A: Maintenance is generally minimal. Routine inspections should ensure lenses are clean and free of obstructions, and the device should be tested periodically to confirm functionality, especially since the unit features automatic alignment for consistent performance.

Q: What are the main benefits of using this beam smoke detector in commercial applications?

A: Key benefits include early smoke detection, coverage of vast areas up to 1,400 sq. meters, flexibility in installation, and low ongoing maintenance. Its EN54-12 certification ensures reliability and compliance with international safety standards.

Price 200000.00 INR/ Unit

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Smoke Detectors Category

Multi Sensor Smoke Detector

Multi Sensor Smoke Detector

Price 1500.00 INR / Unit

Minimum Order Quantity : 1 Unit

Shape : Round

Application : Fire detection and early warning in commercial and residential buildings

Energy Efficiency Rating : Low power consumption

Standalone Smoke Detectors

Standalone Smoke Detectors

Price Range 1200.00 - 1200.00 INR / Unit

Minimum Order Quantity : 1 Unit

Shape : Round

Application : Residential and commercial fire safety

Energy Efficiency Rating : Low power consumption

Photoelectric Smoke Detector

Photoelectric Smoke Detector

Price Range 1300.00 - 1300.00 INR / Unit

Minimum Order Quantity : 1 Unit

Shape : Round

Application : Fire Detection, Building Safety

Energy Efficiency Rating : A+

Wireless Smoke Detector

Wireless Smoke Detector

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Shape : Round

Application : Fire safety in residential and commercial properties

Energy Efficiency Rating : A+



"We mainly deal in end user products such as fire fighting systems."
Back to top