Co2 Suppression System

Co2  Suppression System
Co2  Suppression System

Co2 Suppression System Specification

  • Voltage
  • 24V DC (for solenoid / actuator)
  • Operating Pressure
  • 58.6 bar (850 psi) at 21C
  • Connectivity Type
  • Compatible with fire alarm and control panels
  • Mounting Type
  • Floor-standing and wall-mounted
  • Coverage Area
  • Custom designed up to several hundred square meters based on application
  • Working Temperature
  • -20C to +55C
  • Control Type
  • Automatic & Manual release
  • Installation Type
  • Fixed installation, modular design
  • Coating Type
  • Corrosion resistant epoxy powder coating
  • Features
  • Rapid fire suppression, no residue, electrically non-conductive, eco-friendly
  • Technology
  • Total flooding and local application CO2 gas suppression
  • Fire Extinguisher Type
  • CO2 gas based clean agent
  • Shape
  • Cylindrical cylinder
  • Energy Efficiency Rating
  • Not applicable (passive fire protection system)
  • Fire Class
  • Class B & Class C fires
  • Application
  • Industrial fire protection, Data centers, Power plants, Server rooms, Electrical and electronic equipment protection
  • Max Flow Rate
  • Varies by system configuration, up to 160 lbs/sec
  • Diameter
  • Available in various cylinder diameters (typically 4.25 inches to 10 inches)
  • Capacity
  • 2.5 kg, 5 kg, 10 kg, 22.5 kg, 45 kg, 68 kg, and custom sizes
  • Pressure
  • Stored at 850 psi (58.6 bar) at 21C (70F)
  • System Reset Time
  • Quick reset time for operational readiness
  • Discharge Mechanism
  • High-pressure discharge valve with flexible hose and nozzle
  • Refillable Capacity
  • Cylinders are rechargeable and refillable after use
  • Standards Compliance
  • UL, FM, IS: 6382, NFPA 12
  • Discharge Time
  • Within 60 seconds for protected enclosure
  • Agent Storage
  • Liquefied CO2 under pressure
  • Cylinder Material
  • Seamless steel
  • Color
  • Red
  • Weight
  • Varies depending on cylinder size and CO2 charge
  • Alarm Integration
  • Supports audio and visual pre-discharge alarms
 

Co2 Suppression System Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
 

About Co2 Suppression System



Buy online the extraordinary CO2 Suppression System, available at the lowest price in India. Designed for pivotal industrial fire protection, it features seamless steel cylinders with liquefied CO2 stored under high pressure, discharged within 60 seconds for immediate response. Employing high-pressure valves, flexible hoses, and preeminent alarm integration, its UL, FM, IS: 6382, and NFPA 12 compliance assures optimal safety and reliability. Reduced price offers and refillable cylinders guarantee cost-effectiveness. Its modular design and rapid, residue-free suppression make it pivotal for data centers, power plants, and electronic equipment protection.

Comprehensive Usage & Application Scope

Used as a preeminent fire suppression agent, the CO2 Suppression System is suitable for industrial environments, server rooms, and power plants. Its surface of application includes electrical panels, data centers, and sensitive equipment areas where residue-free, non-conductive fire protection is essential. With both total flooding and local application capabilities, this system delivers extraordinary safety and protects pivotal assets across diverse sectors.


Sample Availability & Supply Logistics

CO2 Suppression System samples are available for assessment to aid purchase decisions. FOB port logistics streamline nationwide delivery in India, ensuring prompt service and supply ability for dealers, retailers, and wholesalers. With various charge capacities and modular options, our supply chain accommodates custom requirements while maintaining quick response and reliable logistical support for efficient system deployment.


FAQs of Co2 Suppression System:


Q: How does the CO2 Suppression System operate during a fire emergency?

A: The system uses high-pressure discharge valves to release liquefied CO2 within 60 seconds into the protected enclosure, quickly suppressing Class B and C fires without leaving residue.

Q: What are the primary usage areas for this CO2 fire suppression system?

A: It is designed for industrial locations, server rooms, data centers, power plants, and environments housing electrical or electronic equipment requiring non-residue, electrically non-conductive protection.

Q: When should the CO2 suppression system be serviced or checked?

A: Regular inspections are recommended as per NFPA 12 and local standards. After any discharge, the cylinders should be refilled and the system reset to maintain operational readiness.

Q: Where is the system installed and how is it mounted?

A: The system features flexible installation options, including floor-standing and wall-mounted cylinders, tailored for both large and compact spaces needing targeted or total flooding protection.

Q: What is the process for refilling and resetting the CO2 cylinders after use?

A: Post-discharge, the seamless steel cylinders are easily recharged and reset, ensuring rapid operational recovery and consistent protection without lengthy downtime.

Q: What benefits does this system offer over traditional fire extinguishing methods?

A: It provides rapid fire suppression with no clean-up required, is safe for sensitive equipment, environmentally friendly, and ensures quick return to normal operations due to its fast reset features.

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Suppression Systems Category

FM 200 Fire Suppression Systems

FM 200 Fire Suppression Systems

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Set

Coverage Area : Up to 200 m (varies by design and system size)

Diameter : 180 mm to 250 mm (varies by cylinder size)

Coating Type : Corrosionresistant coated steel cylinder

Installation Type : Fixed, Preengineered or Engineered Systems

CO2 Fire Suppression Systems

CO2 Fire Suppression Systems

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Coverage Area : Customizable as per design (commonly up to hundreds of Sq. meters)

Diameter : Available from 40 mm to 180 mm (system piping range)

Coating Type : Corrosion resistant red epoxy/Polyester paint

Installation Type : Fixed/Stationary

Novac Fire Suppression Systems

Novac Fire Suppression Systems

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Coverage Area : Up to 100 sq m

Diameter : 150 mm

Coating Type : Corrosion Resistant

Installation Type : Ceiling Mounted

Gas Based Fire Suppression System

Gas Based Fire Suppression System

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Coverage Area : Up to 200 m per system (expandable based on design)

Diameter : Configuration dependent (standard cylinder: 180 mm to 250 mm)

Coating Type : Corrosionresistant, Powder coated

Installation Type : Fixed (Ceiling or Wall Mount)