Gas Based Fire Suppression System

Gas Based Fire Suppression System
Gas Based Fire Suppression System

Gas Based Fire Suppression System Specification

  • Technology
  • Clean Gas Suppression (Inert Gas or Chemical Clean Agent)
  • Operating Pressure
  • Standard 25 bar / 42 bar
  • Connectivity Type
  • Hardwired (integration with fire panels), Network-ready options
  • Shape
  • Cylindrical (standard)
  • Voltage
  • 24V DC (system control panel)
  • Control Type
  • Automatic and Manual
  • Installation Type
  • Fixed (Ceiling or Wall Mount)
  • Coating Type
  • Corrosion-resistant, Powder coated
  • Fire Extinguisher Type
  • Total Flooding Clean Agent System
  • Mounting Type
  • Floor Mounted with Stand or Wall/Cabinet Mountable
  • Fire Class
  • Class A, B, C
  • Coverage Area
  • Up to 200 m per system (expandable based on design)
  • Features
  • Zero-residue, Non-conductive, Fast acting, Eco-friendly, No damage to equipment, Low downtime
  • Energy Efficiency Rating
  • Not applicable (Non-electric, pneumatic and gas powered operation)
  • Working Temperature
  • -10C to +55C
  • Application
  • Server Rooms, Data Centers, Electrical Panels, Archive Rooms, Control Rooms, Telecommunication Facilities, Laboratories, Sensitive Equipment Areas
  • Max Flow Rate
  • Based on agent and design (typical: up to 20 kg/sec)
  • Diameter
  • Configuration dependent (standard cylinder: 180 mm to 250 mm)
  • Capacity
  • 5 kg to 80 kg per cylinder (customization possible)
  • Pressure
  • 25 bar / 42 bar (agent/cylinder dependent)
  • Alarm Integration
  • Can interface with audio/visual alarm systems
  • Noise Level
  • <90 dB (at discharge point)
  • Detection Method
  • Smoke and Heat Detectors (conventional/addressable)
  • Discharge Time
  • Less than 10 seconds
  • Refill & Recharge
  • Onsite or Factory based
  • Agent Type
  • FM-200, Novec 1230, Inergen, CO2 (specified while ordering)
  • Response Time
  • Immediate upon detection (typically 3 seconds)
  • System Life
  • 10-15 years (with proper maintenance)
  • Pipe Material
  • Galvanized Steel, Stainless Steel
  • Release Mechanism
  • Electromechanical Solenoid, Manual Pull Station
  • Cylinder Material
  • Seamless Steel or Alloy Steel
 

Gas Based Fire Suppression System Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
 

About Gas Based Fire Suppression System

Gas Based Fire Suppression System availed by us is designed by using advanced technologies and engineering materials that result in high reliability and sturdiness. This cylinder-based system can be used in residential as well as commercial buildings to greatly reduce the risk of fire hazards. It is equipped with automatic actuators. The elements of the offered Gas Based Fire Suppression System are made up of premium-quality materials that give high durability and strength to bear extreme temperatures and pressures.



Comprehensive Fire Protection Technology

This clean agent gas suppression system utilizes advanced inert and chemical agents such as FM-200, Novec 1230, Inergen, or CO2, providing robust protection against Class A, B, and C fires. Engineered to be zero-residue and non-conductive, it is perfect for environments where sensitive equipment is present and minimizing downtime is critical.


Rapid Detection and Activation

Equipped with both smoke and heat detectorsavailable in conventional or addressable formatsthe system ensures fires are detected promptly, typically triggering suppression within 3 seconds. The release mechanism combines electromechanical solenoids and manual pull stations for both automatic and manual system activation.


Customizable Installation and Coverage

Designed for adaptability, cylinders come in various sizes (5 kg to 80 kg) and can be floor-mounted or wall/cabinet-mounted, with corrosion-resistant coatings for lasting durability. The system supports hardwired and network-ready configurations, allowing easy integration with existing fire panels and alarm solutions.

FAQs of Gas Based Fire Suppression System:


Q: How does the Gas Based Fire Suppression System detect and respond to fire incidents?

A: The system uses advanced smoke and heat detectors, available in both conventional and addressable models, to identify fire threats quickly. Upon detection, it activates the suppression processeither automatically or manuallytypically discharging the agent within 10 seconds, with a rapid response time of less than 3 seconds after fire detection.

Q: What types of fire suppression agents are supported, and how are they chosen?

A: This system supports FM-200, Novec 1230, Inergen, or CO2 agents. The specific agent can be selected at the time of ordering based on the applications requirements, space characteristics, and equipment sensitivity. Each agent provides clean, fast-acting suppression suitable for critical and sensitive areas.

Q: When and where is this system most effective for deployment?

A: Ideally suited to server rooms, data centers, control rooms, archive rooms, telecommunication facilities, laboratories, electrical panels, and other spaces with sensitive equipment, it is effective anywhere swift, clean, and non-damaging fire suppression is paramount.

Q: What is the installation and maintenance process for the system?

A: The system is installed as a fixed unitceiling or wall-mountedand uses seamless steel or alloy steel cylinders with galvanized or stainless steel piping. Maintenance includes periodic inspection and refilling or recharging, which can be done onsite or at authorized factories. With regular servicing, system longevity ranges from 1015 years.

Q: How does the system ensure safety for equipment and occupants during operation?

A: The systems clean agents are non-conductive and leave zero residue, ensuring no corrosion or damage to electronics. It operates at noise levels below 90 dB to minimize disruption, and its eco-friendly design means no harm to people or the environment during discharge.

Q: Can the system be integrated with building alarm and network systems?

A: Yes, the suppression system is designed for flexible connectivity and can interface with audio/visual fire alarm panels via hardwired or network-ready connections, enabling centralized monitoring and control from the buildings fire safety infrastructure.

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 2 Units Per Week
  • Delivery Time
  • 10-15 Days
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Suppression Systems Category

FM 200 Fire Suppression Systems

FM 200 Fire Suppression Systems

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Set

Features : Nonconductive, Residuefree, Rapid discharge, Environmentally safe, No ozone depletion

Voltage : 24V DC (for solenoid & control systems)

Capacity : 8 kg, 16 kg, 30 kg, 40 kg, 80 kg, 100 kg (based on requirement)

Pressure : Superpressurized; 25 bar or 42 bar

Co2  Suppression System

Co2 Suppression System

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Features : Rapid fire suppression, no residue, electrically nonconductive, ecofriendly

Voltage : 24V DC (for solenoid / actuator)

Capacity : 2.5 kg, 5 kg, 10 kg, 22.5 kg, 45 kg, 68 kg, and custom sizes

Pressure : Stored at 850 psi (58.6 bar) at 21C (70F)

Novac Fire Suppression Systems

Novac Fire Suppression Systems

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Features : Ozone Friendly, NonConductive, No Residue, Rapid Discharge

Voltage : 24V DC

Capacity : 5 Kg, 10 Kg, 15 Kg, 30 Kg

Pressure : 25 bar

BOC Fire Suppression system

BOC Fire Suppression system

Price Range 200000.00 - 300000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Features : Environmentally Safe, NonConductive, No Residue, Fast Response

Voltage : 24V DC

Capacity : 5 kg

Pressure : 42 bar



"We mainly deal in end user products such as fire fighting systems."